What is the maximum cooling capacity you provide?
Our Liquid Cooling Systems have the highest cooling capacity in our standard product portfolio. The largest capacity is our Ambient Cooling Systems with cooling capacities up to 5 kW. Custom solutions have been designed with capacities greater than 40 kW’s. The largest capacity of a thermoelectric cooler assembly is our Outdoor Cooler Series AA-480 and it has a cooling capacity of 480 Watts. The largest capacity of a thermoelectric cooler is the HiTemp ETX Series ETX15-28-F2-5252-TA-RT-W6 and it has a cooling capacity of 322 Watts.
What is the maximum ambient temperature that Thermoelectric coolers or assemblies can operate in?
The maximum operating temperature of standard thermoelectric coolers is 80⁰C. For higher temperatures, our HiTemp ETX Series thermoelectric cooler offer cooling for applications with ambient temperatures up to 150°C. For thermoelectric cooler assemblies, the Outdoor Cooler Series has the widest capacity range with an operational capacity from -40°C to +55°C ambient. The SuperCool Series thermoelectric cooler assembly can withstand the highest temperature of 60°C.
What is the Thermal Wizard?
The Thermal Wizard is a product search and selection tool that helps engineers find the optimal thermal management solution for thermoelectric coolers, thermoelectric cooler assemblies and liquid cooling systems.
What is the smallest thermoelectric cooler that LTS provides?
The OptoTEC™ OTX/HTX Series is our smallest thermoelectric module starting at 3.3 x 4.9 x 2.6-mm (LxWxH) with a cooling capacity of 0.4 Watts.
What is the largest size thermoelectric cooler that LTS provides?
Laird Thermal Systems' largest thermoelectric module is the UltraTEC™ UTX Series, 55 x 55 x 3.9 mm (LxWxH).
Are LEXIDE-U16 and LEXIDE-Ω projects compatible?
LEXIDE-Ω is upward compatible with LEXIDE-U16. When using a LEXIDE-U16 project with the LEXIDE-Ω, convert it to a LEXIDE-Ω project. Please follow the steps below to convert to a LEXIDE-Ω project. 1) Select the project and right click 2) Select [Configure] from the pop-up menu 3) Select [Converter to LEXIDE-Ω Project] Note that LEXIDE-Ωprojects cannot be used with the LEXIDE-U16. When converting a LEIXDE-U16 project for LEXIDE-Ω, save the original project before converting.
Is the RF SAW filter needed?
Although it is not needed for meeting the standard, we recommend to insert the RF SAW filter because interfering sources may exist near any actual operation band. Related Products: ML7344/ML7406 family, ML7345 family, ML7396 family, ML7404, ML7414
How can I call a C function from the startup routine?
Use BL instruction to call a C function from the startup routine. Put an underscore (_) at the beginning of a C function name to call. The following shows an example. Example: BL _sub
What is a offset of the rcoa_adjustOscillation function argument described in the ML62Q1000 Series RC Oscillation Correction Sample Software AP Note?
The offset is a value for adjusting the value writing to the low-speed RC oscillation frequency adjustment register. Normally, please use the fixed value 0 as with the sample software.
For BD37033FV-M,BD37034FV-M,BD37524FS,BD37534FV,BD37543FS, What is the level meter function?
The Level Meter is a circuit that outputs a DC voltage proportional to the magnitude of the signal and holds the peak level of the detected signal. Since the held peak level can be reset by resetting the Level Meter, the transition of the peak level can be monitored by periodically performing a reset. The reset interval should be at least one cycle of the frequency to be monitored.
ROHM的PMIC BD9576与BD9573有什么差异?
ROHM的PMIC BD9576支持functional safety(ISO26262),BD9573不支持functional safety。
What is the disconnection detection function?
It is the function that alarms by the signal when the speaker is disconnected with the speaker amplifier and the sound is not played. Related Products: ML22530/Q53x, ML22660/Q66x, ML22Q374/Q394
For Analog Audio Processors, Why is the noise level higher when EQ is on than when EQ is off?
When the EQ is off, the signal does not pass through the equalizer circuit.
There is the silence insertion function on edit ROM function. Do we need to prepare the individual "silent" phrase?
The individual "silent" phrase is not necessary. The silent data ROM size can be reduced using the silence insertion function. Related Products: ML22420/460, ML22530/Q53x, ML2256x/Q563, ML2257x/Q573, ML22594, ML22660/Q66x, ML2272x/76x, ML2282x/86x, ML22Q374/Q394, ML22Q553